| FORM |
Solid without perforation. |
| FACED SURFACES |
The surfaces of the bricks that are faced are shown by shading on the diagrams. Further faces can befaced at additional cost. |
| HANDED BRICKS |
Where there are left and right handed versions this will need to be specified The version shown in thediagram is normally indicated. |
| COMPRESSIVE STRENGTH |
There is not a standard method of measurement in BS 4729. Standard squares when tested under BS3921 are greatly in excess of class 'A' specification. |
| WATER ABSORPTION |
Standard squares are less than 5% when tested to BS 3921 |
| SUCTION RATE |
Typically less than lkg/M2min |
| SOLUBLE SALT CONTENT |
Low |
| LIABILITY TO EFFLORESCENCE |
Nil BS 3921 |
| FROST RESISTANCE |
Frost Resistance (F) BS 3921. Totally durable when saturated and submitted to repeated freezing and thawing. |
| MANUFACTURE |
Etruria Marl fired to 1150° |
| |
|
|
All descriptions, drawings and dimensions displayed on this website are typical of the products and their uses and should not be interpreted as a guarantee of characteristics, and shall not form part of a contract, in addition, although the information is believed to be correct and complete, it should not be regarded as being appropriate to any specific application. and neither the company nor its agents shall be under any liability whatsoever in respect of the contents or for any loss, howsoever caused. |
|
|